FEATURES:
All of our hosting packages come with: Unlimited Full Featured e-mail accounts, unlimited MySQL Databases, unlimited Auto-Responders, unlimited e-mail aliases, unlimited, e-mail forwarders, unlimited add-on domains, unlimited sub-domains.

PAY Monthly $9.95
PAY Yearly $99.95
(2 months free)
PAY Monthly $19.95
PAY Yearly $199.95
(2 months free)
PAY Monthly $59.95
PAY Yearly $599.95
(2 months free)
PAY Monthly $99.95
PAY Yearly $999.95
(2 months free)


ADVANCED FEATURES:
Our packages also include your own hosting control panel (cPanel) and , web mail, 24x7 FTP Account access, FTP Manager, SSH, phpMyAdmin, File Manager, Cron Jobs, Index Manager, Password Protected Directories, Custom Error Pages, FrontPage + Mail Extensions, Downloadable Access Logs, PGP Keys, Network Tools, Apache Handlers, Webalizer + Statistics Tracking, Analog + Statistics Tracking, Server Side Includes (SSI), Php 4.3.x with Zend Optimizer, MySQLv4.x.x, ImageMagick 5.x.x, GD Library 2.x, Search Engine Submitter. Pre installed scripts like Augora Shopping Cart, Interchange Shopping Cart, os Commerce, phpMyChat, php BB, Invision Bulletin Board, Advanced Gurestbook and much more!

DATA CENTER INFORMATION....

Environmental
Cooling and humidity is controlled by more than 12 air handling units (AHUs) featuring N+1 and N+2 redundancy (dependant on location within the center). The system keeps the operating environment in the data center at 68 degrees with 45% humidity with a variation of no more than 8 degrees of temperature and 4% humidity.

Power
Electrical power from Colorado's Xcel Energy is delivered from dual feeds from the Surrey Ridge substation. The electric service in the building is connected to parallel redundant Powerware UPS units, which delivers conditioned power to the data center via a Starline Bussway system. This system eliminates the need for traditional power distribution units (PDU's) and enhances the reliability of the system as well as making "A" and "B" power available to every computer equipment cabinet. The power is backed up by two diesel generators connected to separate automatic transfer switches (ATS).

Fire Detection & Suppression
Fire detection within the Data Center is provided by an early detection alarm system monitored both within the NOC and by Honeywell as a backup third party monitoring service. The monitoring system informs the NOC staff of the specific alarm generating the warning and its location. The data center has sensors installed both above and below the raised floor to detect gases that rise with the airflow in the center as well as heavy gases that tend to settle under the floor. The fire suppression system is a pre-action, dry pipe which would discharge water only from the appropriate locations if the heat in the data center increases enough to trigger a fire sprinkler head. The discharge of a sprinkler would signal the emergency power off switch which would simultaneously turn off the electrical power to the entire data center room.

For more information please contact eric@jrgmedia.com